Search results for "Anova test"

showing 10 items of 17 documents

Accuracy of five intraocular lens formulas in eyes with trifocal lens implant.

2020

Accuracy of intraocular lens (IOL) calculation formulas SRK/T, Hoffer Q, Holladay 1, Haigis and Barrett Universal II were compared in prediction of postoperative refraction for multifocal and implants using a single optical biometry device. The authors included 88 refractive lens exchange and cataract surgeries, with AcrySof IQ PanOptix implant (Alcon Laboratories, Inc.). All eyes were divided into three groups based on axial length (AL), group 1: 24.5 mm (6 eyes). The refractive prediction error (RPE) and mean absolute error (MAE) were calculated for 5 different formulas: SRK/T, Hoffer Q, Holladay 1, Haigis and Barrett Universal II. For eyes with the AL between 22 mm and 24.5 mm the greate…

0301 basic medicineCancer Researchmedicine.medical_specialtymultifocalmedicine.medical_treatmentStatistical differenceIntraocular lens03 medical and health sciences0302 clinical medicineOptical biometryImmunology and Microbiology (miscellaneous)OphthalmologymedicinehydrophobictrifocalMathematicsPanOptixLens implantAnova testArticlesintraocular lens formulasGeneral MedicinePresbyopiamedicine.diseaseAlcon Laboratories030104 developmental biology030220 oncology & carcinogenesispresbyopiaMultifocal IOLsoptical biometryExperimental and therapeutic medicine
researchProduct

Comparison of Immersion Ultrasound, Partial Coherence Interferometry, and Low Coherence Reflectometry for Ocular Biometry in Cataract Patients

2011

PURPOSE: To compare ocular biometry parameters measured with immersion ultrasound, partial coherence interferometry, and low coherence reflectometry in cataract patients. METHODS: Measurements of axial length and anterior chamber depth were analyzed and compared using immersion ultrasound, partial coherence interferometry, and low coherence reflectometry. Keratometry (K), flattest axis, and white-to-white measurements were compared between partial coherence interferometry and low coherence reflectometry. Seventy-eight cataract (LOCS II range: 1 to 3) eyes of 45 patients aged between 42 and 90 years were evaluated. A subanalysis as a function of cataract degree was done for axial length and…

AdultMalemedicine.medical_specialtyBiometryMaterials scienceAnterior ChamberDiagnostic Techniques OphthalmologicalCataractlaw.inventionOpticslawOphthalmologymedicineHumansBody Weights and MeasuresReflectometryAgedUltrasonographyAged 80 and overKeratometerbusiness.industryUltrasoundAnova testAxial lengthMiddle AgedAxial Length EyeOphthalmologyInterferometryInterferometryPartial coherence interferometryFemaleSurgeryUltrasonographybusinessJournal of Refractive Surgery
researchProduct

Efficacy of the NaviTip FX irrigation needle in removing calcium hydroxide from root canal

2012

Objective: To evaluate the effectiveness of the NaviTip FX, brush-covered irrigation needle, in removing calcium hydroxide from the root canal. Study Design: Thirty single-rooted teeth were randomly divided into three groups: A - irrigation with a hypodermic needle inserted as far as possible without binding and activation with #30 K-type file; B - Irrigation with a hypodermic needle without activation; C - irrigation with NaviTip FX needle. Sodium hypoclorite 1% was used in irrigation. The root canals were examined trough scanning electron microscopy. Calcium hydroxide removal was recorded at 1, 5, and 10mm from the working length (WL) and the data were analysed using one-way ANOVA test (p…

IrrigationCalcium hydroxideMICROSCOPIA ELETRÔNICAbusiness.industryResearchRoot canalSignificant differenceAnova testLower scoreSmear layerDentistryOdontología:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludchemistry.chemical_compoundmedicine.anatomical_structurechemistryClinical and Experimental DentistryUNESCO::CIENCIAS MÉDICASmedicinebusinessGeneral DentistryHypodermic needle
researchProduct

Lower incisor position in different malocclusions and facial patterns

2012

Introduction: The position of lower incisor has been of considerable concern when planning an orthodontic treatment, having been recognized as one of diagnostic keys, Very important in the development of malocclusion and facial pattern. Objectives: In this study we claim to determine the importance of the position and inclination of lower incisor in the different malocclusions and facial patterns, and to base which of the cephalometric measurement parameters are the mostreliable. Material and Methods: Ninety lateral radiographies were taken, and they were classified by skeletal malocclusion and facial pattern.These teleradiographies have been performed cephalometric analysis, which includel…

MaleCephalometric analysisCephalometryDentistryOdontologíaOrthodonticsstomatognathic systemIncisorOcclusal planemedicineHumansGeneral DentistryOrthodonticsbusiness.industryAnova testCraniometry:CIENCIAS MÉDICAS [UNESCO]medicine.diseaseCiencias de la saludLower incisorIncisorstomatognathic diseasesPosition (obstetrics)medicine.anatomical_structureOtorhinolaryngologyFaceUNESCO::CIENCIAS MÉDICASFemaleResearch-ArticleSurgeryMalocclusionbusinessPsychologyMalocclusionMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Evaluation of the effect of three innovative recyling methods on the shear bond strength of stainless steel brackets-an in vitro study

2016

Background Orthodontists are commonly faced with the decision of what to do with debonded or inaccurately positioned brackets. An economical option to this dilemma is to recycle the brackets. Many recycling methods have been proposed, but the optimal bond strength of these recycled brackets needs further evaluation. Objectives: To evaluate and compare the effect of three recycling methods: (i) Sandblasting (ii) Sandblasting / direct flaming (iii) Sandblasting /direct flaming /acid bath solution on shear bond strength (SBS) of stainless steel brackets. Material and Methods Eighty human premolars were bonded with premolar stainless steel brackets as per manufacturer’s instructions. The teeth …

Materials sciencePost hocBond strengthResearchGroup iiAnova testOrthodontics030206 dentistryGroup comparison:CIENCIAS MÉDICAS [UNESCO]Shear bond03 medical and health sciences0302 clinical medicineGroup (periodic table)UNESCO::CIENCIAS MÉDICASIn vitro study030212 general & internal medicineComposite materialGeneral Dentistry
researchProduct

Failure of ProTaper rotary Ni-Ti instruments used by undergraduate students

2012

Objective: To evaluate the effect of number of uses, angle and radius of curvature and type of instrument on the fracture of ProTaper rotary instruments when used by undergraduate students. Study Design: Three hundred and seventy-six molars, with a total of 1114 root canals, extracted were instrumented by undergraduate students using ProTaper instruments according to the manufacturer´s recommendations. When fracture occurred, data were collected concerning the number of uses, type of instrument, level of fracture, angle and radius of curvature. ANOVA test were used to determine the influence of type of instrument in the incidence of instrument fracture. Logistic regression model was used to…

OrthodonticsDental materialsbusiness.industryResearchMaterials dentalsDental instruments and apparatusAnova testEstudiants universitarisOdontología:CIENCIAS MÉDICAS [UNESCO]CurvatureOdontologiaCiencias de la saludRadius of curvature (optics)Clinical and Experimental DentistryDentistryUNESCO::CIENCIAS MÉDICASFracture (geology)Aparells i instruments odontològicsMedicineCollege studentsbusinessGeneral Dentistry
researchProduct

Comparison of the accuracy of intraoral digital impression system and conventional impression techniques for multiple implants in the full-arch edent…

2020

Background Several impression techniques, especially in combination with computer-aided design and computer-aided manufacturing (CAD/CAM), are used in increasing the accuracy of dental implantology and decreasing patient discomfort. The study was designed to examine the accuracy of the digital impression (DI) of multiple implants with an intraoral scanner (IOS) and compared with that of a conventional impression (CI). Material and methods Four dental implants were placed in teeth area #33, #36, #43 and 46# of the mandibular full-arch model. The implanted model was replicated by IOS and CI after fitting of scannable abutments over the implant screws. Then, a small hole was made on the scan r…

OrthodonticsProsthetic Dentistry0303 health sciencesIntraoral scannerScannerbusiness.industryResearchEdentulous mandibleAnova testpeople.profession030206 dentistryDental technicianImpression03 medical and health sciences0302 clinical medicineMedicineImplantArchpeoplebusinessGeneral DentistryUNESCO:CIENCIAS MÉDICAS030304 developmental biologyJournal of Clinical and Experimental Dentistry
researchProduct

Perceived barriers to the provision of preventive care among dentists of Udaipur, India

2015

Aim: To investigate the practice-, patient- and dentist related barriers to the provision of preventive dental care as perceived by dentists of Udaipur city, Rajasthan, India. Settings and Design:- A cross sectional descriptive survey was conducted among 120 dentists of Udaipur city, Rajasthan. Material and Methods: Mean Content Validity Ratio (CVR) was calculated as 0.87 based on the opinions expressed by a panel of total six academicians. Cronbach's coefficient was found to be 0.88, which showed a high internal reliability of the questionnaire. The questionnaire consisted of demographic questions and 12 specific research questions. Statistical analysis used:- Student's t-test and ANOVA te…

Pediatricsmedicine.medical_specialtybusiness.industryResearchSignificant differenceAlternative medicineAnova testOdontología:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludCommunity and Preventive DentistryPreventive careHealth promotionCronbach's alphaStatistical significanceFamily medicineUNESCO::CIENCIAS MÉDICASmedicineContent validitybusinessGeneral DentistryUncategorizedJournal of Clinical and Experimental Dentistry
researchProduct

Analysis of fit on implants of chrome cobalt versus titanium frameworks made by cad / cam milling

2020

Background This study analyzed the degree of passive and vertical fit achieved in frameworks using either cobalt-chromium (Co-Cr) or titanium (Ti) implant-supported fixed partial dentures ( FPDs) fabricated with a CAD/CAM milling technique. Material and Methods 33 3-unit FDPs, 17 of Co-Cr metal alloy (test group) and 16 of Ti (control group), were manufactured with two implants by copy milled technology. Optical microscopy was used to measure passive fit (PF) and vertical fit (VF) in all frameworks. The PF was evaluated by using the Single Screw test and the VF with the screws tightened at 20 Ncm. Descriptive and inferential analysis were performed to evaluate statistically significant diff…

Prosthetic DentistryMaterials scienceMetal alloyTest groupResearchAnova testchemistry.chemical_element:CIENCIAS MÉDICAS [UNESCO]chemistryUNESCO::CIENCIAS MÉDICASFixed partial denturesImplantGeneral DentistryImplant supportedChrome cobaltBiomedical engineeringTitaniumJournal of Clinical and Experimental Dentistry
researchProduct

The Influence of Friction on Design of the Type of Bracket and Its Relation to OHRQoL in Patients Who Use Multi-Bracket Appliances: A Randomized Clin…

2021

Background and objectives: The aim of this study was to evaluate the influence of friction on design of the type of bracket, patients’ perception of pain and the impact on their oral health-related quality of life. Materials and Methods: A randomized clinical trial was carried out with 90 patients (62.2% women and 37.8% men) with three kinds of fixed multi-bracket appliances: Conventional (GC), fixed multi-bracket low friction (GS) and self-ligating (GA). The VAS (Visual Analogue Scale) was used to determine pain during the first seven days of treatment at different points in time. The patients were also given the OHIP-14 (Oral Health Impact Profile) questionnaire to analyse their oral heal…

Salud bucalFrictionOrthodontic BracketsVisual analogue scaleInvestigación médicaDentistryOdontologíaOral healthArticlelaw.inventionsymbols.namesakeorthodontics; pain; quality of life; low-friction brackets; oral healthQuality of lifeRandomized controlled triallawMaterials TestingOrthodontic WiresHumansOrthodontic Appliance DesignMedicineIn patientpainlcsh:R5-920business.industryBracketAnova testGeneral Medicinelow-friction bracketsBonferroni correctionquality of lifesymbolsoral healthbusinesslcsh:Medicine (General)orthodonticsSoportes ortodóncicos
researchProduct